International Customers:
Click Here | Contact Us
G4X PlugIn ECUs offer the latest in engine management technology, designed to easily maximize the potential from your car.
This ECU fits inside the factory OEM enclosure. Installation is a breeze, with no alteration of the factory wiring loom required for the models listed below.
The NGTRX is Designed to suit the blue plug Nissan RB engine.
Suitable applications:
RB26DETT engines found in R32, R33, R34 Skyline GTRs and Autech 260RS Stageas
RB20DE engines found in R32 & R33 Skylines, A31 Cefiros
RB20DET engines found in R32 Skylines (incl 4wd), A31 Cefiros and C33 Laurels. – Injector 4&6 need swapping
RB25DE engines found in R32 & R33 Skylines, C33 & C34 Laurels and A31 Cefiros.
RB25DET engines found in R33 Skylines (incl 4wd) and C34 Laurels
RB30DE/DET/DETT engines made using Non Neo heads and blue plug looms
Note: This Plug-in features a new 4 pin powered CAN connector and cannot use the old CANPCB cable for CAN connection. Use the CANJST4 (Code 101-0198) cable for connecting CAN devices. This new 4 pin port and cable provide not only the CAN connection, but also a protected 12V power supply and ground for powering the CAN devices. The power supply is protected by a self-resetting fuse rated at 3A continuous.
Up to 6D fuel and ignition mapping
Precision closed loop cam control (four cam, independent control)
Sequential fuel delivery
Digital triggering, all OEM patterns
OEM idle hardware supported
5D boost control with three switchable tables
Motorsport features - antilag, launch, flat shift
Continuous barometric correction (on board)
CAN port
QuickTune - automated fuel tuning
Individual cylinder correction
USB tuning cable included
Stats recording into on-board memory
Gear compensations for spark, boost and fuel
Real time selectable dual fuel, ignition and boost maps
Sync and crank sensors can be a combination of Hall effect, variable reluctance or optical
Boost control referenced to gear, speed or throttle position
512 mega bytes data logging memory
Staged injection
Knock with "windowing"
I/O Expansion Options:
The following expansion connector inputs/outputs are provided:
Expansion connector 1
Gnd Sensor Ground Only
+5V Out Low Current +5V Supply
DI5 Digital Input
DI6 Digital Input
An Volt 8 Analog 0-5V input
An Volt 2 Analog 0-5V input
An Temp 3 Temperature sensor input
An Temp 4 Temperature sensor input
Expansion connector 2
Gnd Sensor Ground Only
+5V Out Low Current +5V Supply
Ign 7 Ignition 7 Auxiliary Output
Ign 8 Ignition 8 Auxiliary Output
DI 9 Digital Input
DI 10 Digital Input
An Volt 10 Analog 0-5V input
Aux 11 Auxiliary Output 11